Interface Methods
The isolated logic inputs may be interfaced to the user’s control system in a
variety of ways. In all cases the inputs are normally in a logic HIGH state when
left floating. For purposes of this manual we will show three interface methods:
1] Switch Interface.
2] Open Collector Interface.
3] TTL Interface.
We will also show IM483 inputs connected to the IMS LYNX modular motion
controller, which is a powerful machine control soulution.
Switch Interface
A switch connected between the input and the opto supply ground will sink the
input. If this method is used a SPST (Single-Pole, Single-Throw) switch works
well for enable and direction. A normally-open momentary switch works well
for reset. Figure 7.6 illustrates a SPST switch connected to the direction input.
Direction P1:3
Opto Supply P1:4
+5 VDC
Opto Supply
+
GND
Figure 7.6: Switch Interface